amplifyeyecare-logo-base2-icon
Authors
Momeni-Moghaddam, Hamed; Goss, David A.; Dehvari, Abubakr

Vergence Facility with Stereoscopic and Nonstereoscopic Targets

publication date
August 20, 2008
Category
see more

Abstract/Introduction

Purpose 

To compare vergence facility with nonstereo and stereo targets in binocular symptomatic and asymptomatic subjects.

 

Methods 

Sixty-six students were divided into symptomatic and asymptomatic groups according to the Convergence Insufficiency Symptom Survey Questionnaire score. Vergence facility was tested at 40 cm by flipper prism 3Δ BI/12Δ BO (BI, base-in; BO, base-out). The targets used were a nonstereo target (a vertical column of small letter “E” of ~20/30 size), a stereo-local target (fifth set of circles of the Titmus test with stereoacuity of 100 arcsec), and a stereo-global target (page 6 of the TNO test with stereoacuity of 120 arcsec).


Conclusion/Results

Results 

Repeated-measures analysis of variance showed differences in the mean vergence facility with different targets in all subjects and separately in two symptom groups (p < 0.001). In all subjects and separately in the symptomatic subjects, this difference was statistically significant among the three different targets (p < 0.05). In the asymptomatic subjects, this difference was not significant between the measured values with nonstereo and stereo-local targets (p > 0.05) but significant for the comparison of stereo-global targets with the other two targets. The receiver operating characteristic curve analysis showed the cutoff points 10.5, 10.5, and 9.75 cycles per minute with nonstereo, stereo-local, and stereo-global targets, respectively. The sensitivity of the three targets used was the same (97%). Specificity was 0.93 or higher with all three targets, with the highest specificity obtained with the stereo-global target (100%).

 

Conclusions 

The highest vergence facility was obtained with a nonstereo target and the lowest was obtained with a stereo-global target. High sensitivity with all three targets means that there are few false-negative results with them, and the high specificity is indicative of low false-positive results. Hence, the vergence facility predictive value would be high in diagnosing binocular symptomatic patients using a 3Δ BI/12Δ BO prism flipper at near and a response cutoff of about 10 cycles per minute or less.


Contact Us To Amplify Your EyeCare

Learn More 

arrow-uparrow-right